14.2

Parameter list | C02626

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02626

C02627

C02637

Parameter | Name:

C02626 | Manual jog:Index Stop position

Data type: INTEGER_32

Index: 21949

d

= 55BD

h

From software version V5.0

Selection of the breakpoint positions for "

Manual jog with breakpoint

" mode.

• In connection with a function block instance of type L_PosPositionerTable:

The index [1...75] of the table position in the VTPOS table has to be specified, which contains the intermediate

stop position x that is to be used.

• In connection with a function block instance of type L_PosProfileTable:

The index [1...4] of the profile data set in the VTPOS table has to be specified, which contains the intermediate

stop position x that is to be used.

Basic function "

Manual jog

"

Setting range

(min. value | unit | max. value)

0

75

Subcodes

Lenze setting

Info

C02626/1

0

Index of the breakpoint positions 1 ... 16

C02626/...
C02626/16

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02627 | Manual jog:Selected Stop position

Data type: INTEGER_32

Index: 21948

d

= 55BC

h

From software version V5.0

Display of the breakpoint positions selected via

C02626/1...16

for "

Manual jog with breakpoints

".

Basic function "

Manual jog

"

Display range

(min. value | unit | max. value)

-214748.3648

Unit

214748.3647

Subcodes

Info

C02627/1

Breakpoint position 1 ... 16

C02627/...
C02627/16

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C02637 | MAN_dnSpeedOverride_n

Data type: INTEGER_32

Index: 21938

d

= 55B2

h

From software version V5.0

Display of the speed override for the basic function "

Manual jog

".

Display range

(min. value | unit | max. value)

-200.00

%

200.00

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100