Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

807

14

Parameter reference

14.2

Parameter list | C00625

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00625

C00635

C00636

C00637

Parameter | Name:

C00625 | CAN behaviour in case of fault

Data type: UNSIGNED_8

Index: 23950

d

= 5D8E

h

Mapping of the CANopen object

I-1029

(see DS301 V4.02).

"CAN on board" system bus

Selection list

(Lenze setting printed in bold)

0 Pre-operational state
1 No state change
2 Stopped state

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00635 | Resp to new firmw. standard dev.

Data type: UNSIGNED_32

Index: 23940

d

= 5D84

h

Selection list

(Lenze setting printed in bold)

1 Fault
6 Information
5 Warning
4 Warning locked
3 Quick stop by trouble
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00636 | Resp. to new module in MXI1

Data type: UNSIGNED_32

Index: 23939

d

= 5D83

h

Selection list

(Lenze setting printed in bold)

1 Fault
6 Information
5 Warning
4 Warning locked
3 Quick stop by trouble
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00637 | Resp. to new module in MXI2

Data type: UNSIGNED_32

Index: 23938

d

= 5D82

h

Selection list

(Lenze setting printed in bold)

1 Fault
6 Information
5 Warning
4 Warning locked
3 Quick stop by trouble
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1