C00952 | vfc: frequency interpol. point n, C00953 | vfc: voltage interpol. point n, C00952/1 – Lenze 9400 User Manual

Page 823: C00953/1, C00952, C00953, 14 parameter reference

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

823

14

Parameter reference

14.2

Parameter list | C00952

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00952

C00953

Parameter | Name:

C00952 | VFC: Frequency interpol. point n

Data type: INTEGER_32

Index: 23623

d

= 5C47

h

From software version V3.0

V/f control

Setting range

(min. value | unit | max. value)

-5000

Hz

5000

Subcodes

Lenze setting

Info

C00952/1

-50 Hz

C00952/2

-40 Hz

C00952/3

-30 Hz

C00952/4

-20 Hz

C00952/5

-10 Hz

C00952/6

0 Hz

C00952/7

10 Hz

C00952/8

20 Hz

C00952/9

30 Hz

C00952/10

40 Hz

C00952/11

50 Hz

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00953 | VFC: Voltage interpol. point n

Data type: INTEGER_32

Index: 23622

d

= 5C46

h

From software version V3.0

V/f control

Setting range

(min. value | unit | max. value)

0.00

V

1000.00

Subcodes

Lenze setting

Info

C00953/1

400.00 V

C00953/2

320.00 V

C00953/3

240.00 V

C00953/4

160.00 V

C00953/5

80.00 V

C00953/6

0.00 V

C00953/7

80.00 V

C00953/8

160.00 V

C00953/9

240.00 V

C00953/10

320.00 V

C00953/11

400.00 V

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Advertising
This manual is related to the following products: