C00071 | speed contr. reset time, C00072 | speed contr.d component, C00074 | feedfwd. ctrl. - current contr – Lenze 9400 User Manual

Page 739: C00075 | current controller gain, C00076 | current contr. reset time, C00077 | field controller gain, C00071, C00075, C00076, Are not alte

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

739

14

Parameter reference

14.2

Parameter list | C00071

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00071

C00072

C00074

C00075

C00076

C00077

Parameter | Name:

C00071 | Speed contr. reset time

Data type: UNSIGNED_32

Index: 24504

d

= 5FB8

h

Setting range

(min. value | unit | max. value)

Lenze setting

1.0

ms

6000.0 14.4 ms

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Parameter | Name:

C00072 | Speed contr.D component

Data type: UNSIGNED_32

Index: 24503

d

= 5FB7

h

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

ms

3.00 0.00 ms

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00074 | Feedfwd. ctrl. - current contr.

Data type: UNSIGNED_8

Index: 24501

d

= 5FB5

h

Selection list

(Lenze setting printed in bold)

0 Deactivate feedfwd. ctrl
1 Activate feedfwd. ctrl

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00075 | Current controller gain

Data type: UNSIGNED_32

Index: 24500

d

= 5FB4

h

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

V/A

750.00 105.00 V/A

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00076 | Current contr. reset time

Data type: UNSIGNED_32

Index: 24499

d

= 5FB3

h

Setting range

(min. value | unit | max. value)

Lenze setting

0.01

ms

2000.00 2.00 ms

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00077 | Field controller gain

Data type: UNSIGNED_32

Index: 24498

d

= 5FB2

h

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

A/Vs

50000.00 165.84 A/Vs

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Advertising