11 basic drive functions – Lenze 9400 User Manual

Page 488

Advertising
background image

11

Basic drive functions

11.8

Position follower

488

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Internal variables of the motor control (oscilloscope signals)

• The red numbers in brackets listed in the signal flow stand for internal variables of the motor

control, which you can record by means of the

Oscilloscope

for purposes of diagnostics and

documentation.

( 579)

No. Variable of the motor control

Meaning

(1)

Torque.dnTotalTorqueAdd

Additive torque feedforward control value

(2)

Torque.dnTorqueSetpoint

Torque setpoint

(3)

Position.dnActualLoadPos

Actual position

(4)

Position.dnPositionSetpoint

Position setpoint

(5)

Position.dnActualMotorPos

Current motor position

(6)

Position.dnContouringError

Following error

(7)

Speed.dnOutputPosCtrl

Output signal - phase controller

(8)

Speed.dnSpeedSetpoint

Speed setpoint

(9)

Speed.dnActualMotorSpeed

Current motor speed

Advertising