Parameter list | C00321

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00321

C00322

Parameter | Name:

C00321 | CAN RPDOx identifier

Data type: BITFIELD_32

Index: 24254

d

= 5EBE

h

Identifier for RPDO1 ... RPDO4

• If bit 31 is set (0x8nnnnnnn), the RPDO is deactivated.

• The basic setting is according to the "Predefined Connection Set".

• Mapping of the CANopen objects

I-1400/1

...

I-1403/1

(see DS301 V4.02).

"CAN on board" system bus

Setting range
0x00000000

0xFFFFFFFF

Value is bit-coded:

Info

Bit 0 COB-ID bit 0

• Bit 0 ... 10: COB-ID

• Bit 11 ... 30: Reserved

• Bit 31: PDO invalid

... ...

Bit 31 PDO invalid

Subcodes

Lenze setting

Info

C00321/1

0x00000201

RPDO1 identifier

• After a node address change and CAN reset node, the

value 0x200 + node address will be set by default.

C00321/2

0x00000301

RPDO2 identifier

• After a node address change and CAN reset node, the

value 0x300 + node address will be set by default.

C00321/3

0x00000401

RPDO3 identifier

• After a node address change and CAN reset node, the

value 0x400 + node address will be set by default.

C00321/4

0x00000501

Identifier RPDO4

• After a node address change and CAN reset node, the

value 0x500 + node address will be set by default.

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00322 | CAN TPDOx Tx mode

Data type: UNSIGNED_8

Index: 24253

d

= 5EBD

h

TPDO transmission type according to DS301 V4.02

• Types 0 (acyclic sync), 1-240 (cyclic sync), 254 (event-controlled manufacturer-specific), 255 (event-controlled

device-profile-specific) are supported.

• The basic PDO setting is "254" (event-controlled).

• Mapping of the CANopen objects

I-1800/2

...

I-1803/2

(see DS301 V4.02).

"CAN on board" system bus

Setting range

(min. value | unit | max. value)

0

255

Subcodes

Lenze setting

Info

C00322/1

254

Transmission mode for TPDO1 ... TPDO4

C00322/...
C00322/4

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1