C00106 | quick stop s-ramp time, C00107 | ref. for quick stop dec. time, C00114 | dig. input x: terminal polarity – Lenze 9400 User Manual

Page 743: C00118 | dig. output. x: terminal polarity, C00114, Terised in, C00118, Into, C00106, C00107

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

743

14

Parameter reference

14.2

Parameter list | C00106

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00106

C00107

C00114

C00118

Parameter | Name:

C00106 | Quick stop S-ramp time

Data type: UNSIGNED_32

Index: 24469

d

= 5F95

h

S-ramp time in [%] relating to the deceleration time set under

C00105

.

Basic function "

Quick stop

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

100.00 0.00 %

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00107 | Ref. for quick stop dec. time

Data type: UNSIGNED_8

Index: 24468

d

= 5F94

h

Reference for the deceleration time set in

C00105

.

Basic function "

Quick stop

"

Selection list

(Lenze setting printed in bold)

0 Motor reference speed (C00011)
1 Current speed

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00114 | Dig. input x: Terminal polarity

Data type: UNSIGNED_8

Index: 24461

d

= 5F8D

h

"0" = positive logic (HIGH level = TRUE, LOW level = FALSE)

"1" = negative logic (HIGH level = FALSE, LOW level = TRUE)
Setting range

(min. value | unit | max. value)

0

1

Subcodes

Lenze setting

Info

C00114/1

0

Terminal polarity - digital input 1 ... 8

C00114/...
C00114/8

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00118 | Dig. output. x: Terminal polarity

Data type: UNSIGNED_8

Index: 24457

d

= 5F89

h

"0" ≡ positive logic (TRUE ≡ HIGH level, FALSE ≡ LOW level)

"1" ≡ negative logic (FALSE ≡ HIGH level, TRUE ≡ LOW level)
Setting range

(min. value | unit | max. value)

0

1

Subcodes

Lenze setting

Info

C00118/1

0

Terminal polarity - digital output 1 ... 4

C00118/...
C00118/4

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Advertising