5 optimising response to setpoint changes, Optimising response to setpoint changes, 5motor interface – Lenze 9400 User Manual

Page 154

Advertising
background image

5

Motor interface

5.4

Servo control (SC)

154

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.4.1.5

Optimising response to setpoint changes

Setting the load moment of inertia under

C00273/2

does not always provide the optimum torque

feedforward control. Depending on the application, an adjustment of the setting under

C00273/2

may be necessary to optimise the response to position/speed setpoint changes by means of the

torque feedforward control.

[5-4]

Typical signal characteristics for different settings of the load moment of inertia

Apart from the load moment of inertia, effects can be compensated with

C00273/2

, which in the

closed speed control loop are identified by the speed controller. These for example include the

friction torques.
Below you will find a description of a procedure for optimising the feedforward control behaviour

starting from the system's moment of inertia.

Without feedforward control:

C00273/2

set too low:

C00273/2

set too high:

Optimum feedforward control:

Speed setpoint (Speed.dnSpeedSetpoint signal)

Actual speed value (Speed.dnActualMotorSpeed signal)

Speed controller output (Torque.dnOutputSpeedCtrl signal)

Torque feedforward control (Torque.dnTotalTorqueAdd signal)

n, M

t

Ž

Œ



t

Œ





Ž

n, M

t

Œ





Ž

n, M

t

Œ





Ž

n, M

Advertising
This manual is related to the following products: