Motor interface

5.5

Sensorless vector control (SLVC)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.5

Sensorless vector control (SLVC)

This function extension is available from software version V3.0!

If this motor control mode is set in

C00006

, a considerably higher torque and a lower current

consumption in idle state can be achieved compared to the V/f control mode.

Tip!
For vertical drives/hoists, use the servo control (with feedback), or the V/f control with

activated voltage vector control (VVC), which supports vertical drives/hoists up to 55 kW.

Note!

Observe the following application limits of the sensorless vector control:

• Only approved for power up to 55 kW and horizontal applications (no hoists or lifting

equipment)

• For single drives only
• For asynchronous motors only
• Not suitable for operation in generator mode/braking operation (e. g. unwinders)