Motor interface

5.5

Sensorless vector control (SLVC)

166

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.5.2

Optimising motor parameters

Although the motor parameters have been determined before as described in the chapter

"

Adjusting motor and controller to each other

", an additional optimisation may be required in the

following cases using the adjustment processes described in this chapter:

• When the concentricity factor in the lowest speed range is to be improved.
• When the stability in the lower speed range is to be improved.
• When the rated torque is not reached in the rated point, i. e. at rated speed and rated current.
• When a too high magnetising current is injected in idle state.

General information on the motor parameter adjustment
The motor stator resistance can generally always be adjusted with a passive load since the motor is

stopped when this parameter is set.
An optimisation of the mutual motor inductance, however, is only sensible when the motor rotates

in the medium speed range. In the majority of cases, the no-load operation is sufficient for this

adjustment. In contrast to the rated operation, the no-load operation is also possible for initial

commissioning in many applications.
The motor rotor resistance can only be adjusted exactly if the current motor speed is available. Thus,

for this adjustment only applications are considered where a speed measurement is possible, even

with a manual tachometer. If, under operating conditions (e.g. at rated load), the motor consumes

more than the rated motor current indicated, an adjustment can also be executed by reducing the

mutual motor inductance.

Note!

To execute the adjustment processes described in the following subchapters, the

controller must always be enabled!