4 signal flow, Signal flow, 5motor interface – Lenze 9400 User Manual

Page 180: 5 sensorless vector control (slvc) 180

Advertising
background image

5

Motor interface

5.5

Sensorless vector control (SLVC)

180

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.5.4

Signal flow

[5-15] Signal flow - sensorless vector control

Internal variables of the motor control (oscilloscope signals)

• The red numbers in brackets listed in the signal flow stand for internal variables of the motor

control, which you can record by means of the

Oscilloscope

for purposes of diagnostics and

documentation.

( 579)

C00776

C02559/1...2

C00052

M

I

a +b

2

2

C00987

C00280

C00783

C00018

C00079

C00091

(8)

(9)

(10)

M

C00988

MI_dnTorqueSetpoint_n

MI_bCurrentSetpointLimited

a +b

2

2

MI_dnActualMotorCurrent_n

MI_dnActualMotorVoltage_n

MCTRL_dwMotorVoltageAct

MCTRL_dnImotAct

C00780

C00054

MI_bTorqueSetpointLimited

C00497

C00985

MI_dnTorqueHighLimit_n

MI_dnTorqueLowLimit_n

C00695

C00986

(1)

(2)

(3)

(4)

(5)

(11)

(12)

(3)

(10)

usq

usd

C00059

C00051

(6)

(7)

MI_dnActualFlux_n

C00778 MCTRL_dnFluxAct

Voltage limit

Motor model

Motor voltage

Switching frequency

Filter - DC detection

Internal torque limits

Filter time constant

Coordinate
transformation

Motor current

Inverter error
characteristic

Gain

Feedforward
control

Reset time

Actual speed value

Number of pole pairs

Torque controller

Slip calculation

Actual Q-current

Actual D-current

Field controller

Feedforward
control

f(C00022, Pull-out slip limitation)

Actual Q-current

Actual D-current

Torque setpoint

Flux model

Field weakening

No. Variable of the motor control

Meaning

(1)

Torque.dnTorqueSetpoint

Torque setpoint

(2)

Current.dnQuadratureCurrentSet

Q current setpoint

(3)

Current.dnActualQuadratureCurrent

Actual Q current

(4)

Speed.dnActualMotorSpeed

Actual speed value

(5)

Common.dnActualFlux

Actual flux value

(6)

Frequency.dnActualSlipFrequency

Actual slip frequency

(7)

Frequency.dnActualRotatingFieldFrequency Actual field frequency

(8)

Voltage.dnQuadratureVoltage

Q voltage

(9)

Voltage.dnDirectVoltage

D voltage

(10) Voltage.dnActualMotorVoltage

Current motor voltage

(11) Current.dnDirectCurrentSet

D current setpoint

(12) Current.dnActualDirectCurrent

Actual D current

Advertising
This manual is related to the following products: