2 field weakening for synchronous machines, Field weakening for synchronous machines, Field weakening for – Lenze 9400 User Manual

Page 206: Synchronous machines, Field weakening for synchronous machines ( 206), V2.0, 5motor interface

Advertising
background image

5

Motor interface

5.8

Parameterisable additional functions

206

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.8.2

Field weakening for synchronous machines

This function is available from software version V2.0!

If required, the field weakening mode can be switched on in

C00093

for synchronous machines.

[5-28] Voltage/speed characteristic with switched-on field weakening

[5-29] Calculation of the maximally reachable speed with switched-on field weakening

[5-30] Speed/torque characteristics of a synchronous servo motor with field weakening

Note!

Function only possible for servo control!

Armature control range

Field weakening range

• When field weakening is switched on, the motor

magnetising current is increased from 0 A to the maximally

effective magnetising current via an internal control loop

when the voltage limit is reached.

• As a result, a higher speed can be reached at the same

motor voltage or DC-bus voltage.

n

Œ



U

motor

n

max

n

rated_mot

800V

2 U

rated_mot

--------------------------------------

=

 Standstill torque

 Rated torque

Characteristic for continuous operation

Limit characteristic at mains voltage of 400 V without field weakening

Limit characteristic with field weakening

0

10

20

30

40

50

60

M [Nm]

Œ



0

1500

3000

4500

Ž

0

1

n [rpm]