3 "ls_digitaloutput" system block, Ls_digitaloutput" system block, 8i/o terminals – Lenze 9400 User Manual

Page 282

Advertising
background image

8

I/O terminals

8.5

Digital outputs

282

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.5.3

"LS_DigitalOutput" system block

In the function block editor the LS_DigitalOutput system block provides the interface to the digital

outputs, the state bus, and the yellow user LED at the front of the controller.

Input

DIS code | data type

Information/possible settings

DIGOUT_bOut1

C00444/1

| BOOL

...

DIGOUT_bOut4

C00444/4

| BOOL

Digital output 1 ... 4

DIGOUT_bStateBusOut

C00444/18

| BOOL

Setting the state bus to the "Error" state

"State bus" monitoring function ( 283)

TRUE The state bus is set to LOW level, all nodes connected to the state bus

start their pre-programmed response.

DIGOUT_bUserLED

C00444/9

| BOOL

Control of yellow user LED on the front of the controller

TRUE LED on

GO

24O

DO1

DO2

DO3

DO4

LS_DigitalOutput

DIGOUT_bOut1

DIGOUT_bStateBusOut

DIGOUT_bOut3

DIGOUT_bOut2

X4

1

0

1

C00118/1...4

DIGOUT_bOut4

DIGOUT_bUserLED

User LED

C00444/1...4

GE

24E

SB

X2

CONTROL

Advertising