1 actual value interpolation (principle), Actual value interpolation (principle), 8i/o terminals – Lenze 9400 User Manual

Page 286

Advertising
background image

8

I/O terminals

8.7

Touch probe detection

286

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.7.1

Actual value interpolation (principle)

If a touch probe is detected, the (remaining) time until the following task cycle is determined and

from this a time stamp is generated. On the basis of this time stamp, the L_SdTouchProbe FB can

then carry out a linear interpolation between the two actual position interpolation points; the

result is the precise actual position at the time of the physical touch probe event.

[8-3]

Actual value determination through linear interpolation (principle)

Actual position point 1

Actual position point 2

 Residual time (dnTouchProbeTimeLag)

Data

processing

Application

Data

processing

Application

Data

processing

Application

Task cycle

Task cycle

Task cycle

t

Position

t

0

Œ



t

1

p

1

p

2

Touch probe received