369

10

Safety engineering

10.3

System block "LS_SafetyModuleInterface"

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

10.3.1

Status information

Via the bit-coded status signal SMI_dnState of the LS_SafetyModuleInterface SB, the SM3xx safety

module transmits the status of safety functions to the application.

• Which bits are supported depends on the safety module used.

Tip!
For decoding the status signal into individual boolean status signals, simply connect the

output SMI_dnState to the L_DevSMStateDecoder FB which is available in the function

library from V2.0.

Bit coding of the status signal SMI_dnState

Bit

Name

Meaning

0

STO

"Safe torque off (STO)" function is active.

• The drive is safely switched to torqueless operation.

3

EC_STO

Error stop category 0: "Safe torque off (STO)" function is active.

4

EC_SS1

Error stop category 1: "Safe stop 1 (SS1)" function is active.

5

EC_SS2

Error stop category 2: "Safe stop 2 (SS2)" function is active.

8

SLS1 monitored

Safely limited speed 1 is activated and complied with.

9

SLS2 monitored

Safely limited speed 2 is activated and complied with.

10

SLS3 monitored

Safely limited speed 3 is activated and complied with.

11

SLS4 monitored

Safely limited speed 4 is activated and complied with.

12

SDIpos monitored

Safe positive direction of rotation (SDIpos) is activated and complied with.

13

SDIneg monitored

Safe negative direction of rotation (SDIneg) is activated and complied with.

14

Fault active

SM3xx safety module has the error status (trouble or warning).

Bits not listed are reserved for future extensions!