2 parameter setting, 11 basic drive functions – Lenze 9400 User Manual

Page 389

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

389

11

Basic drive functions

11.3

Quick stop

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Inputs

Outputs

11.3.2

Parameter setting

• Parameterisation dialog in »Engineer«: Tab Application parameter  Dialog level Overview

All basic functions Quick stop

• Short overview of the parameters for quick stop:

Identifier

DIS code | data type

Information/possible settings

QSP_bActivate1

C02619/1

| BOOL

QSP_bActivate2

C02619/2

| BOOL

QSP_bActivate3

C02619/3

| BOOL

Activate quick stop

• The three inputs are linked via a logic OR gate.

TRUE If one of the three inputs is set to TRUE, a change-over to the "Quick

stop active" function state is effected and the drive is brought to

standstill within the deceleration time set for quick stop.

TRUEFALSE If all three inputs are reset to FALSE, a change-over to a setpoint-

generating basic function (e. g. "Speed follower") via the "Drive is

stopped" function state is effected.

QSP_bActivateDCBrake

C02619/5

| BOOL

From V3.0

Activate

DC-injection braking

.

( 392)

• Only possible if V/f control or sensorless vector control is selected as motor

control type in

C00006

!

• This input has a higher priority than the three inputs QSP_bActivate1 ... 3.

TRUE A change-over to the "Quick stop active" function state is effected

and the drive is decelerated with the braking current set in

C00974

.

TRUEFALSE DC-injection braking is activated again.

• If flying restart is activated in

C00990

, a flying restart process is

automatically started to determine the current motor speed.

Identifier

DIS code | data type

Value/meaning

QSP_bActive

C02619/4

| BOOL

Status signal "Quick stop by application active"

QSP_bActive is not set to TRUE if quick stop has been activated by another source,

e. g. via device command or as an error response ("Quick stop by trouble").

TRUE Quick stop has been requested via one of the three inputs

QSP_bActivate1 ... 3 and is active.

- or -

DC-injection braking

has been requested via QSP_bActivateDCBrake

and is active (only for motor control mode without encoder).

Parameter

Info

C00105

Decel. time - quick stop

C00106

Quick stop S-ramp time

C00107

Reference for quick stop deceleration time

Advertising