1 dc-injection braking and flying restart process, 11 basic drive functions – Lenze 9400 User Manual

Page 393

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

393

11

Basic drive functions

11.3

Quick stop

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.3.4.1

DC-injection braking and flying restart process

[11-14] Process example: speed follower is active  QSP_bActivateDCBrake is active  speed follower is active

A. Initial situation: basic function "Speed follower" is enabled and active.
B. QSP_bActivateDCBrake control input is set to TRUE through the application to activate DC-

injection braking.

C. DC-injection braking is executed with the braking current set in

C00974

.

D. QSP_bActivateDCBrake control input is reset to FALSE through the application to deactivate DC-

injection braking.

E. The flying restart process starts, i.e. the controller calculates the output frequency required for

the momentary motor speed, then connects to the system, and accelerates the motor to the

defined setpoint again.

C00974

: Braking current

t

t

Enable speed follower

t

Speed setpoint

Speed follower active

DC brake active

Œ

t

Quick stop active

t

TRUE

FALSE

bActivateDCBrake

0

1

2

3

4

Actual

speed

t

DC brake current

Advertising
This manual is related to the following products: