4drive interface – Lenze 9400 User Manual

Page 40

Advertising
background image

4

Drive interface

4.1

Machine parameters

40

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.1.9

Max. position, speed, and acceleration that can be displayed internally

By setting the following machine parameters, the connection between the real units (application

units) of the machine and the internal units in the controller is described:

• Gearbox ratio (

C02520

,

C02521

,

C02522

,

C02523

)

• Feed constant (

C02524

)

• Resolution of an encoder revolution (

C00100

)

Possibly the defined values for position, speed, and acceleration cannot be represented in the

internal units by the numerical 32-bit format used.

• The following display parameters show the values that can be maximally displayed:

Response if a value that cannot be displayed internally is entered
If a position, speed, or acceleration which cannot be represented internally is defined via

parameters, the value defined is limited to the maximum value that can be represented internally

(±2147483647).

Parameter

Info

Lenze setting

Value Unit

C02539

Max. presentable position

- Unit

C02540

Speed that can be maximally displayed

- Unit/s

C02541

Acceleration that can be maximally displayed

- Unit/s

2

Greyed out = display parameter

Advertising
This manual is related to the following products: