Mode 1035: ds402 homing method 35, 5 execute homing, 11 basic drive functions – Lenze 9400 User Manual

Page 471

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

471

11

Basic drive functions

11.6

Homing

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Mode 1035: DS402 homing method 35

Direct reference setting.

11.6.5

Execute homing

Requirements

• The controller is in the "Operation" device state.
• The basic function "Homing" is part of the active application.
• No other basic function is active.

Activation
To request the control via the basic function, the HM_bEnable enable input in the application must

be set to TRUE.

• If no other basic function is active, a change-over to the "Homing active" function state is

effected and homing can be carried out via the control inputs.

• A successful change to the "Homing active" function state is displayed by a TRUE signal at the

HM_bEnabled status output.

Deactivation
When the HM_bEnable enable input is reset to FALSE, an active homing is stopped, i.e. the control

inputs for homing are inhibited and the drive is braked to standstill within the deceleration time for

stop.

• The status output HM_bEnabled is reset to FALSE and a change-over from the active "Homing

active" function state via the "Drive is stopped" function state back to the basic state "Drive at

standstill" is carried out.