11.6

Homing

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.6.5.3

Resetting home position

By setting the control input HM_bResetHomePos to TRUE, the "Home position known" status can be

reset.

• The status outputs HM_bDone and HM_bHomePosAvailable are reset to FALSE.

Note!

For the encoderless motor control types

(from software version V3.0)

the following

applies:
If V/f control or sensorless vector control has been selected, this function is only effective

if the position controller has also been selected for the position control

(

C02570

= "2: position controller active").

For the encoderless motor control types

(from software version V5.0)

the following

applies:
If the V/f control or sensorless vector control is selected, this function can be activated

irrespective of the use of the position controller.