11 limiter, 1 internal interfaces | "ls_limiter" system block, Limiter – Lenze 9400 User Manual

Page 502: Function, E basic function, Nction, Basic function, 11 basic drive functions

Advertising
background image

11

Basic drive functions

11.11

Limiter

502

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.11

Limiter

The basic function "Limiter" monitors the travel range limits via limit switches and parameterised

software limit positions and can lead the drive to defined limit ranges when being requested

accordingly by the safety module.

See also:

Safety engineering

( 366)

11.11.1

Internal interfaces | "LS_Limiter" system block

The LS_Limiter system block provides the internal interfaces for the basic function "Limiter" in the

function block editor.

Danger!

The safety is exclusively ensured by the safety module!
When the request for the safety function is cancelled, the drive can restarts

automatically.
Ensure by external measures that the drive only starts after a confirmation (EN 60204).

Note!

In order to make it possible for the basic function "Limiter" to lead the drive to the limit

ranges defined after a corresponding request by the safety module, before the limits set

for the safety module have been reached and it shuts down the drive, the limits for the

basic function "Limiter" have to be set lower than the limits of the safety module!

Note!

Ensure that the system block is called in a cyclic application task.
Basically, projects which only contain an unsolicited task and no cyclic task are not

permissible!

LS_Limiter

LIM_dwControl

LIM_bLimitSwitchPositive

LIM_bLimitSwitchNegative

LIM_dnState

n

t

LIM_bActivateLimitedSpeed1

LIM_bLimitationActive

Advertising