4 product/track change-over, 11 basic drive functions – Lenze 9400 User Manual

Page 567

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

567

11

Basic drive functions

11.13

Cam data management

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.13.4

Product/track change-over

Product change-over
The change-over to another product number is effected for all cam FBs within the application via

the basic function "Cam data management".

• The change-over is effected via the input CAM_bActivateProduct on the basis of an event that is

generated from the application.

• By setting the input CAM_bActivateProduct to TRUE, the product is activated with the product

number at input CAM_dnProductNumber.

[11-52] Principle: Product change-over

Track change-over
The change-over to another curve track, cam track, or position track, however, is individually

effected via the input dnTrackNumber at the respective cam function block.

• For the two FBs L_CamProfiler and L_CamContactor it can be parameterised whether the track

change-over is to be effected in the next zero crossing of the x axis or immediately (Lenze

setting: in the next zero crossing).

[11-53] Principle: Track change-over

 Product number

 Activate product change-over

/6B&DP,QWHUIDFH

&$0BGQ3URGXFW1XPEHU

"

L



&$0BE$FWLYDWH3URGXFW



 Track number of the curve track

 Track number of the cam track

 Track number of the position track

/B&DP&RQWDFWRU

GQ7UDFN1XPEHU

"

L



/B&DP3RV0DUNHU

GQ7UDFN1XPEHU

"

L



/B&DP3URILOHU

GQ7UDFN1XPEHU

"

L



Advertising
This manual is related to the following products: