Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

585

12

Oscilloscope

12.4

Operation

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

12.4.3

Selecting the trigger condition

The trigger condition serves to define the starting time of recording in the controller. The

oscilloscope provides various trigger conditions by means of which recording of the measured

values can be controlled.

If the Cursor tab is in the front, click the Trigger register to show the input fields for

configuring the trigger condition.

Setting

Function

Direct trigger

Selection of trigger source:

Variable The oscilloscope triggers on any variable of the PLC program.

• Unlike triggering on a channel, triggering on a variable requires no recording channel.

Channel The oscilloscope triggers on a channel configured in the Vertical table.

System event Triggering is started on occurrence of a selectable controller event (e.g. TRIP, trouble or

warning).

• Select a negative trigger delay to record signals prior to occurrence of the event.

Force trigger No trigger condition, recording starts immediately after the start.

Trigger value

Value from which on triggering is activated.

• The trigger level is not effective for triggering on Boolean variables.

Delay

Delay between recording and trigger event.

Pre-trigger Select a negative delay time to detect signals prior to the trigger event.

• In the oscillograph, the trigger time is marked by a dotted line.

• When triggering on occurrence of an event, it is thus possible to detect the values that

have caused the event.

Post-trigger Select a positive delay time to detect signals occurring a certain time after the trigger event.

Trigger event

Trigger

delay

(negative)

Trigger level

Trigger event

Trigger

delay

(positive)

Trigger level