Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

593

12

Oscilloscope

12.5

Managing oscillograms (measured data records)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

12.5.4

Closing an oscillogram

You can close an open offline data record at any time.

• After a data record is closed, it is not available anymore in the Oscillogram list field. The

oscilloscope changes automatically to the display of the ONLINE data record.

• If the closed data record was included in the MERGE data record, its channels will be removed

from the MERGE data record.

Go to the Oscilloscope toolbar and click the

symbol to close the currently displayed

offline data record.

12.5.5

Overlay function

The overlay function serves to lay several characteristics from the currently loaded data records on

top of each other, e.g. to compare signal characteristics from different recordings.

• If two or more data records are loaded in the oscilloscope, e.g. the online data record and a data

record saved before in the project, a "merge" data record is automatically provided in the

Oscillogram list field.

• If the merge data record is selected, the desired characteristics to be overlaid or compared can

be selected from the loaded data records in the Vertical channel settings group field.

• If an online data record is used in the merge data record, an update is carried out in the merge

data record in case of a renewed recording.

• Removing variables from an OFFLINE or ONLINE data record causes the characteristics in the

MERGE data record to be deleted.