1 functional description, 2 filtering logbook entries, Filtering – Lenze 9400 User Manual

Page 604: Logbook entries, 13 diagnostics & fault analysis

Advertising
background image

13

Diagnostics & fault analysis

13.4

Logbook

604

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

13.4.1

Functional description

The structure of the logbook corresponds to a ring buffer:

[13-3] Ring buffer structure

13.4.2

Filtering logbook entries

The logbook enters new entries in the ring buffer after they have passed through a parameterisable

filter. By means of this filter you can exclude events with a specific error response (trouble, warning,

information, etc.) from being entered in the logbook.

The filter is parameterised in

C00169

by means of a bit mask. A set bit inhibits the entry of the

corresponding event in the logbook.

From software version V5.0

the option that identical consecutive entries ("Multiple entries")

into the logbook are suppressed can be additionally activated via bit 0. Then only the time

stamp of the last (latest) entry and the number of times the same event has occurred

successively are saved.

• As long as free logbook memory is available, the entry is placed in

the next free position within the memory ().

• If all memory units are assigned, the oldest entry () is deleted for

a new entry.

• The newest entries will always remain available.





Q

Q

Q

Q

Q[

Q

Note!

Events with the "No response" setting are not entered into the logbook.

Bit

Filter

Lenze setting

0

No multiple entries

0 ≡ filter inactive

1

Fault

0 ≡ filter inactive

2

Trouble

0 ≡ filter inactive

3

Quick stop by trouble

0 ≡ filter inactive

4

Warning locked

0 ≡ filter inactive

5

Warning

0 ≡ filter inactive

6

Information

0 ≡ filter inactive

Advertising