3 reading out logbook entries, 13 diagnostics & fault analysis – Lenze 9400 User Manual

Page 605

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

605

13

Diagnostics & fault analysis

13.4

Logbook

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

13.4.3

Reading out logbook entries

With an online connection, the existing logbook entries can easily be displayed in the »Engineer«.

Alternatively, the logbook entries can also be read out via the corresponding parameters (e.g. using

the keypad).

How to display logbook entries in the »Engineer«:

1. Go to the Project view and select the 9400 HighLine controller the logbook entries of which

are to be read out.

2. Click the

icon or select the OnlineGo online command to build up an online

connection with the controller.

3. Select the Diagnostics tab from the Workspace.

4. Click the

symbol in the diagnostics toolbar to open the Logbook dialog box.

The Logbook dialog box displays all logbook entries available in the device. You can filter the entries

displayed systematically by selecting or defining filter criteria.

Button

Function

Export...

Export logbook entries to a file ( 606)

Storing in the project Storing logbook entries in the project. Logbook entries stored in the project are also

displayed if there is no online connection to the controller (e.g. for service and

documentation purposes).

Deleting in the device Delete all logbook entries available in the device.

Advertising
This manual is related to the following products: