Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

611

13

Diagnostics & fault analysis

13.7

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

13.7.1.1

Response

The state of the internal device control changes according to the selected response to an error,

controller inhibit is set, and the "DRIVE ERROR" LED on the front of the controller goes on:

13.7.1.2

Instance ID

The instance ID is dynamically assigned by the operating system.

Bit 31

Bit 30

Bit 29

Response

0

0

0

0: No response

0

0

1

1: Fault

0

1

0

2: Trouble

0

1

1

3: Quick stop by trouble

1

0

0

4: Warning locked

1

0

1

5: Warning

1

1

0

6: Information

1

1

1

7: System fault

Response

Logbook entry

Display in

C00168

Pulse inhibit

Controller inhibit

Acknowledgeme

nt required

LED

"DRIVE ERROR"

None

OFF

Information

OFF

Warning

Warning locked

Quick stop by

trouble

Trouble

(after 0.5 s)

Fault

System fault

Mains

switching

is required!

Bit 31

16

25

26

28

29

0

15

Bit 28

Bit 27

Bit 26

Meaning

0

0

0

Instance ID 0

0

0

1

Instance ID 1

0

1

0

Instance ID 2

0

1

1

Instance ID 3

1

0

0

Instance ID 4

1

0

1

Instance ID 5

1

1

0

Instance ID 6

1

1

1

Instance ID 7

Bit 31

16

25

26

28

29

0

15