Memory module is missing [0x00650003, Control card is defect [0x00680000, Power section is defect [0x00680001 – Lenze 9400 User Manual

Page 624: Memory module is defect or missing [0x00680002, 0x00680000, 0x00680002, 0x00650003, 0x00680001, 13 diagnostics & fault analysis

Advertising
background image

13

Diagnostics & fault analysis

13.7

Error messages of the operating system

624

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Memory module is missing [0x00650003]

Control card is defect [0x00680000]

Power section is defect [0x00680001]

Memory module is defect or missing [0x00680002]

Module ID (decimal)

Error ID (decimal)

101: Logbook module

3

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Memory module is defective or not available.

Use a different memory module.

Module ID (decimal)

Error ID (decimal)

104: Module identification

0

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Operating system could not identify the control card.

Mains switching

• Please contact Lenze if the error occurs again.

Module ID (decimal)

Error ID (decimal)

104: Module identification

1

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Operating system could not identify the power section. Mains switching

• Please contact Lenze if the error occurs again.

Module ID (decimal)

Error ID (decimal)

104: Module identification

2

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Operating system could not identify the memory

module.

Mains switching

• If the error occurs again: Switch off the controller,

remove memory module and plug in again, switch on

the controller again.

• If the error still occurs: Switch off controller and use a

different memory module.

Advertising
This manual is related to the following products: