Safety module is defect or missing [0x00680003, Mxi1: module changed during operation [0x00680004, Mxi2: module changed during operation [0x00680005 – Lenze 9400 User Manual

Page 625: Memory module has been removed [0x00680006, 0x00680006, 0x00680004, 0x00680005, 0x00680003, 13 diagnostics & fault analysis

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

625

13

Diagnostics & fault analysis

13.7

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Safety module is defect or missing [0x00680003]

MXI1: Module changed during operation [0x00680004]

MXI2: Module changed during operation [0x00680005]

Memory module has been removed [0x00680006]

Module ID (decimal)

Error ID (decimal)

104: Module identification

3

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Operating system could not identify the safety module. Mains switching

• If the error occurs again: Switch off the controller,

remove safety module and plug in again, switch on

the controller again.

• If the error still occurs: Switch off controller and use a

different safety module.

Module ID (decimal)

Error ID (decimal)

104: Module identification

4

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

It was tried to plug an extension module into module slot

MXI1, which is not "Hot-plug"-able.

Plug in valid module and switch on mains.

• Through mains switching, the system accepts

modules without "hot plug" capability in the

following switch-on phase.

Module ID (decimal)

Error ID (decimal)

104: Module identification

5

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

It was tried to plug an extension module into module slot

MXI2, which is not "Hot-plug"-able.

Plug in valid module and switch on mains.

• Through mains switching, the system accepts

modules without "hot plug" capability in the

following switch-on phase.

Module ID (decimal)

Error ID (decimal)

104: Module identification

6

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

You have tried to remove or change the memory module

during operation.

Switch off the controller, plug in memory module and

switch on the controller again.

• If the error occurs again, the memory module is

defective and must be replaced.