Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

635

13

Diagnostics & fault analysis

13.7

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Internal error (file system lifetime) [0x0069000d]

General error in the application [0x006a0000]

Faulty program download [0x006a0001]

Fault during the update of the inputs and outputs [0x006a0002]

Module ID (decimal)

Error ID (decimal)

105: Error check of the program memory during runtime

13

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The maximum number of permissible writing cycles has

been reached for the memory module.

Replace memory module, otherwise data may get lost.

Module ID (decimal)

Error ID (decimal)

106: Runtime environment for IEC 61131-3 programs

0

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

General application error.

Mains switching. Transmit the application to the

controller again.

• Please contact Lenze if the problem occurs again.

Module ID (decimal)

Error ID (decimal)

106: Runtime environment for IEC 61131-3 programs

1

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Faulty transmission of the application to the controller

(checksum error).

Repeat transmission.

Module ID (decimal)

Error ID (decimal)

106: Runtime environment for IEC 61131-3 programs

2

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Internal error

Mains switching. Transmit the application to the

controller again.

• Please contact Lenze if the problem occurs again.

Advertising