Internal communication error (dma) [0x007b0034, Plc configuration invalid [0x007b0037, 0x007b0035 – Lenze 9400 User Manual

Page 658: 0x007b0034, 0x007b0036, 0x007b0038, 0x007b0037, 13 diagnostics & fault analysis

Advertising
background image

13

Diagnostics & fault analysis

13.7

Error messages of the operating system

658

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Internal communication error (DMA) [0x007b0034]

Controller: Overload during acceleration phases [0x007b0035]

Internal communication error (MCTRL host) [0x007b0036]

PLC configuration invalid [0x007b0037]

Motor parameter identification was cancelled [0x007b0038]

Module ID (decimal)

Error ID (decimal)

123: Motor control

52

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Internal error.

Please contact Lenze.

Module ID (decimal)

Error ID (decimal)

123: Motor control

53

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Frequent or too long acceleration processes.

• Check drive dimensioning.

• Reduce steepness of acceleration ramps.

Module ID (decimal)

Error ID (decimal)

123: Motor control

54

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Internal error.

Please contact Lenze.

Module ID (decimal)

Error ID (decimal)

123: Motor control

55

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

An invalid control configuration has occurred.

Load a different application.

Module ID (decimal)

Error ID (decimal)

123: Motor control

56

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The motor current during identification was too high.

• The motor must not move during identification.

• Check motor parameters.

Advertising