13

Diagnostics & fault analysis

13.7

Error messages of the operating system

690

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

CAN module (MXI1) SDO client: Faulty configuration [0x00a30000]

DFIN (MXI2): Track error A-/A [0x00aa0000]

DFIN (MXI2): Track error B-/B [0x00aa0001]

DFIN (MXI2): Track error Z-/Z [0x00aa0002]

Module ID (decimal)

Error ID (decimal)

163: CAN module in MXI1: CAN-SDO client

0

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

CANopen communication module in MXI1: In the CAN

SDO client a configuration error has occurred.

• Faulty project download.

• Invalid SDO client settings according to DS301V402 in

the Engineer or PLC Designer.

• Repeat download

• Correct CAN settings in the project and regenerate

project.

Module ID (decimal)

Error ID (decimal)

170: Extension module - digital frequency in MXI2

0

Response (Lenze setting printed in bold)

Setting:

C14040

( Adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Digital frequency extension module in MXI2:

Interruption (open circuit) of the signal cable for track A.

• Check signal cable for track A.

• Check encoder.

Module ID (decimal)

Error ID (decimal)

170: Extension module - digital frequency in MXI2

1

Response (Lenze setting printed in bold)

Setting:

C14040

( Adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Digital frequency extension module in MXI2:

Interruption (open circuit) of the signal cable for track B.

• Check signal cable for track B.

• Check encoder.

Module ID (decimal)

Error ID (decimal)

170: Extension module - digital frequency in MXI2

2

Response (Lenze setting printed in bold)

Setting:

C14040

( Adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Digital frequency extension module in MXI2:

Interruption (open circuit) of the signal cable for track Z.

• Check signal cable for track Z.

• Check encoder.

Advertising