Plc configuration invalid [0x00b80000, Positive limit switch has triggered [0x00b80001, 0x00b20000 – Lenze 9400 User Manual

Page 697: 0x00b10000, 0x00b80000, 0x00b80001, 13 diagnostics & fault analysis

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

697

13

Diagnostics & fault analysis

13.7

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

CAN module (MXI2) SDO server: Faulty configuration [0x00b10000]

CAN module (MXI2) SDO client: Faulty configuration [0x00b20000]

PLC configuration invalid [0x00b80000]

Positive limit switch has triggered [0x00b80001]

Module ID (decimal)

Error ID (decimal)

177: CAN module in MXI2: CAN-SDO server

0

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

CANopen communication module in MXI2: In the CAN

SDO server a configuration error has occurred.

• Faulty project download.

• Invalid SDO server settings according to DS301V402

in the Engineer or PLC Designer.

• Repeat download.

• Correct CAN settings in the project and regenerate

project.

Module ID (decimal)

Error ID (decimal)

178: CAN module in MXI2: CAN-SDO client

0

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

CANopen communication module in MXI2: In the CAN

SDO client a configuration error has occurred.

• Faulty project download.

• Invalid SDO client settings according to DS301V402 in

the Engineer or PLC Designer.

• Repeat download

• Correct CAN settings in the project and regenerate

project.

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

0

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

An invalid control configuration has occurred.

Load a different application.

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

1

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The

travel range limit switch

in positive traversing

direction has tripped.

Reset fault message and

retract limit switch

.

Advertising
This manual is related to the following products: