C00008 | progress of device command, C00011 | motor reference speed, C00018 | switching frequency – Lenze 9400 User Manual

Page 734: C00019 | threshold - standstill recognition, C00018, C00011, Highline, D set in, E speed, C00019

Advertising
background image

14

Parameter reference

14.2

Parameter list | C00008

734

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00008

C00011

C00018

C00019

Parameter | Name:

C00008 | Progress of device command

Data type: UNSIGNED_32

Index: 24567

d

= 5FF7

h

From software version V7.0

Display range

(min. value | unit | max. value)

0

4294967295

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00011 | Motor reference speed

Data type: UNSIGNED_32

Index: 24564

d

= 5FF4

h

For parameter setting via interface: In case of bigger changes, only change the setting in one step when the

controller is inhibited!
Setting range

(min. value | unit | max. value)

Lenze setting

50

rpm

50000 3000 rpm

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00018 | Switching frequency

Data type: UNSIGNED_32

Index: 24557

d

= 5FED

h

Selection list

(Lenze setting printed in bold)

Info

2 1 kHz fixed/drive-optimised

Note:

• The maximum output frequency of the controller is

limited to 1/8 of the switching frequency selected

here!

• The switching frequencies that can be selected

depend on the device type (see Hardware Manual,

chapter "Rated data").

• In the case of an offline parameter setting or when

exchanging the memory module between different

Servo Drives 9400 HighLine device types, always

check the setting of this parameter and adapt it, if

required, to prevent a parameter error after the

parameter set download or module change!

3 2 kHz fixed/drive-optimised
4 4 kHz fixed/drive-optimised
5 8 kHz fixed/drive-optimised
8 2 kHz var./drive-optimised
9 4 kHz var./drive-optimised

10 8 kHz var./drive-optimised
11 16 kHz var./drive-optimised

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00019 | Threshold - standstill recognition

Data type: UNSIGNED_32

Index: 24556

d

= 5FEC

h

Setting range

(min. value | unit | max. value)

Lenze setting

0

rpm

450 5 rpm

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1