C00022 | maximum current, C00034 | config. analog input 1, C00050 | speed setpoint [rpm – Lenze 9400 User Manual

Page 735: C00051 | actual speed [rpm, C00052 | motor voltage, C00022, A" in, He maximum current, C00052, When

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

735

14

Parameter reference

14.2

Parameter list | C00022

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00022

C00034

C00050

C00051

C00052

Parameter | Name:

C00022 | Maximum current

Data type: UNSIGNED_32

Index: 24553

d

= 5FE9

h

Note:

• To avoid that the motor starts unintentionally without adjusting the plant data, the maximum current in the

Lenze setting is set to "0 A"!

• The upper limit value is the maximum device current (see display in

C00789

).

• In the case of an offline parameter setting or when exchanging the memory module between different 9400

HighLine device types, always check the setting of this parameter and adapt it, if required, to prevent a

parameter error after the parameter set download or module change!

• Also check the threshold set for the maximum motor current monitoring (

C00620

).

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

A

21474836.47 0.00 A

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00034 | Config. analog input 1

Data type: UNSIGNED_32

Index: 24541

d

= 5FDD

h

Selection list

(Lenze setting printed in bold)

0 -10 ... +10 V
1 -20...-4 mA, +4...+20 mA
2 -20 ... +20 mA

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00050 | Speed setpoint [rpm]

Data type: INTEGER_32

Index: 24525

d

= 5FCD

h

Display range

(min. value | unit | max. value)

-480000

rpm

480000

Subcodes

Info

C00050/1

Speed setpoint 1 [rpm]

C00050/2

Speed setpoint 2 [rpm]

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00051 | Actual speed [rpm]

Data type: INTEGER_32

Index: 24524

d

= 5FCC

h

Display range

(min. value | unit | max. value)

-480000

rpm

480000

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00052 | Motor voltage

Data type: UNSIGNED_32

Index: 24523

d

= 5FCB

h

Display range

(min. value | unit | max. value)

0

V

2147483647

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1