C00058 | pole position, C00059 | motor - number of pole pairs, C00060 | rotor position – Lenze 9400 User Manual

Page 737: C00061 | heatsink temperature, C00062 | temperature inside the controller, C00063 | motor temperature, C00058, C00059, C00060, C00058/1

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

737

14

Parameter reference

14.2

Parameter list | C00058

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00058

C00059

C00060

C00061

C00062

C00063

Parameter | Name:

C00058 | Pole position

Data type: INTEGER_32

Index: 24517

d

= 5FC5

h

Setting range

(min. value | unit | max. value)

-179.9

°

179.9

Subcodes

Lenze setting

Info

C00058/1

-90.0 °

Resolver pole position

C00058/2

0.0 °

Encoder pole position

C00058/3

0.0 °

Module pole position

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Parameter | Name:

C00059 | Motor - number of pole pairs

Data type: UNSIGNED_32

Index: 24516

d

= 5FC4

h

Display range

(min. value | unit | max. value)

0

200

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00060 | Rotor position

Data type: INTEGER_32

Index: 24515

d

= 5FC3

h

Display range

(min. value | unit | max. value)

0

2047

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00061 | Heatsink temperature

Data type: INTEGER_32

Index: 24514

d

= 5FC2

h

Display range

(min. value | unit | max. value)

-200

°C

200

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00062 | Temperature inside the controller

Data type: INTEGER_32

Index: 24513

d

= 5FC1

h

Display range

(min. value | unit | max. value)

-200

°C

200

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00063 | Motor temperature

Data type: INTEGER_32

Index: 24512

d

= 5FC0

h

Motor temperature monitoring

Display range

(min. value | unit | max. value)

-200

°C

200

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Advertising