14.2

Parameter list | C00084

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00084

C00085

C00087

C00088

C00089

C00090

Parameter | Name:

C00084 | Motor stator resistance

Data type: UNSIGNED_32

Index: 24491

d

= 5FAB

h

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Ohm

125.0000 18.2200 Ohm

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10000

Parameter | Name:

C00085 | Motor stator leakage inductance

Data type: UNSIGNED_32

Index: 24490

d

= 5FAA

h

Setting range

(min. value | unit | max. value)

Lenze setting

0.000

mH

500.000 51.000 mH

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1000

Parameter | Name:

C00087 | Rated motor speed

Data type: UNSIGNED_32

Index: 24488

d

= 5FA8

h

Setting range

(min. value | unit | max. value)

Lenze setting

50

rpm

50000 4050 rpm

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00088 | Rated motor current

Data type: UNSIGNED_32

Index: 24487

d

= 5FA7

h

Setting range

(min. value | unit | max. value)

Lenze setting

0.01

A

1500.00 1.30 A

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00089 | Rated motor frequency

Data type: UNSIGNED_32

Index: 24486

d

= 5FA6

h

Setting range

(min. value | unit | max. value)

Lenze setting

0.1

Hz

1000.0 270.0 Hz

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Parameter | Name:

C00090 | Rated motor voltage

Data type: UNSIGNED_32

Index: 24485

d

= 5FA5

h

Setting range

(min. value | unit | max. value)

Lenze setting

50

V

15000 225 V

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Advertising