C00120 | mot. overload protection (i·xt), C00121 | warning threshold motor temperature, C00122 | heatsink temp. warn. threshold – Lenze 9400 User Manual

Page 744: C00123 | warning threshold device util, C00123, Reshold set in, C00120, C00121, C00122, 14 parameter reference

Advertising
background image

14

Parameter reference

14.2

Parameter list | C00120

744

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00120

C00121

C00122

C00123

Parameter | Name:

C00120 | Mot. overload protection (I²xt)

Data type: UNSIGNED_32

Index: 24455

d

= 5F87

h

Threshold for I

2

x t disconnection

• Disconnection is carried out if the thermal motor load (

C00066

) is higher than the set threshold.

• A 100 % thermal motor load corresponds to a permanently flowing rated motor current

Note:

When the value is parameterised to 200 %, the monitoring mode of the motor overload protection is switched off!

I2xt motor monitoring

Setting range

(min. value | unit | max. value)

Lenze setting

0

%

200 105 %

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00121 | Warning threshold motor temperature

Data type: UNSIGNED_32

Index: 24454

d

= 5F86

h

Temperature threshold for motor temperature advance warning

• The response to reaching the threshold can be selected in

C00584

.

Motor temperature monitoring

Setting range

(min. value | unit | max. value)

Lenze setting

0

°C

150 120 °C

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00122 | Heatsink temp. warn. threshold

Data type: UNSIGNED_32

Index: 24453

d

= 5F85

h

Temperature threshold for heatsink temperature advance warning

• The response to reaching the threshold can be selected in

C00582

.

Setting range

(min. value | unit | max. value)

Lenze setting

0

°C

85 85 °C

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00123 | Warning threshold device util.

Data type: UNSIGNED_32

Index: 24452

d

= 5F84

h

Adjustable threshold for I x t advance warning

• The advance warning is sent if the device utilisation (

C00064

) is higher than the set threshold.

• The response to reaching the threshold can be selected in

C00604

.

Setting range

(min. value | unit | max. value)

Lenze setting

0

%

100 90 %

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1