C00126 | cpu temp. warning threshold, C00127 | mot. overload warning threshold, C00128 | therm. motor time constant – Lenze 9400 User Manual

Page 745: C00129 | brake resistance value, C00128/1, C00128/2, E advance warning threshold set n, C00127, The error m, C00129

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

745

14

Parameter reference

14.2

Parameter list | C00126

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00126

C00127

C00128

C00129

Parameter | Name:

C00126 | CPU temp. warning threshold

Data type: UNSIGNED_32

Index: 24449

d

= 5F81

h

Temperature threshold for advance warning of CPU temperature on the control card

• The response to reaching the threshold can be selected in

C00589

.

Setting range

(min. value | unit | max. value)

Lenze setting

0

°C

85 70 °C

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00127 | Mot. overload warning threshold

Data type: UNSIGNED_32

Index: 24448

d

= 5F80

h

Adjustable threshold for I

2

x t advance warning

• The advance warning is sent if the thermal motor load (

C00066

) is higher than the set threshold.

• The response to reaching the threshold can be selected in

C00606

.

I2xt motor monitoring

Setting range

(min. value | unit | max. value)

Lenze setting

0

%

200 100 %

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00128 | Therm. motor time constant

Data type: UNSIGNED_32

Index: 24447

d

= 5F7F

h

I2xt motor monitoring

Setting range

(min. value | unit | max. value)

0.1

min

600.0

Subcodes

Lenze setting

Info

C00128/1

1.0 min

Therm. time constant coil

C00128/2

5.0 min

Therm. time constant plates

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Parameter | Name:

C00129 | Brake resistance value

Data type: INTEGER_32

Index: 24446

d

= 5F7E

h

Required for monitoring of the brake resistor temperature.

Braking operation

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

Ohm

500.0 180.0 Ohm

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Advertising