C00205 | hw descriptions, C00206 | hw manufacturing data, C00208 | hw manufacturer – Lenze 9400 User Manual

Page 758: C00205, C00206, C00208, 14 parameter reference

Advertising
background image

14

Parameter reference

14.2

Parameter list | C00205

758

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00205

C00206

C00208

Parameter | Name:

C00205 | HW descriptions

Data type: VISIBLE_STRING

Index: 24370

d

= 5F32

h

Subcodes

Info

C00205/1

Info: Control card

C00205/2

Info: Power section

C00205/3

Info: Module in MXI1

C00205/4

Info: Module in MXI2

C00205/5

Info: Memory module

C00205/6

Info: Safety module

Read access  Write access  CINH  PLC-STOP  No transfer

Scaling factor: 1

Character length: 18

Parameter | Name:

C00206 | HW manufacturing data

Data type: VISIBLE_STRING

Index: 24369

d

= 5F31

h

Subcodes

Info

C00206/1

Date: Control card

C00206/2

Date: Power section

C00206/3

Date: Module in MXI1

C00206/4

Date: Module in MXI2

C00206/5

Date: Memory module

C00206/6

Date: Safety module

C00206/7

Date: Standard device

C00206/8

Date: Complete device

Read access  Write access  RSP  PLC-STOP  No transfer

Scaling factor: 1

Character length: 20

Parameter | Name:

C00208 | HW manufacturer

Data type: VISIBLE_STRING

Index: 24367

d

= 5F2F

h

Subcodes

Info

C00208/1

Manufacturer: Control card

C00208/2

Manufacturer: Power section

C00208/3

Manufacturer: Module in MXI1

C00208/4

Manufacturer: Module in MXI2

C00208/5

Manufacturer: Memory module

C00208/6

Manufacturer: Safety module

Read access  Write access  RSP  PLC-STOP  No transfer

Scaling factor: 1

Character length: 20

Advertising