C00227 | behaviour due to change of parameter set, C00254 | phase controller gain, C00270 | freq. - current setpoint filter – Lenze 9400 User Manual

Page 761: C00271 | width - current setp. filter, C00270/1, C00270/2, C00271/1, C00271/2, Y in, C00272/1

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

761

14

Parameter reference

14.2

Parameter list | C00227

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00227

C00254

C00270

C00271

Parameter | Name:

C00227 | Behaviour due to change of parameter set

Data type: UNSIGNED_32

Index: 24348

d

= 5F1C

h

From software version V5.0

By selecting "1" in the corresponding subcode a module plugged into module slot MXI1 or MXI2 can be excepted

from the parameter set changeover via the device command "Activate parameter set n".

• By this the parameter set changeover, in particular for active modules, is carried out much more quickly.

• An exception from the parameter set changeover for instance is reasonable if different parameter sets are used

(e. g. for different tools within the machine), but if the parameters are always the same for the module (e. g.

communication parameters).

Selection list

(Lenze setting printed in bold)

0 Included
1 Excluded

Subcodes

Lenze setting

Info

C00227/1

0: Included

Change of parameter set: MXI1

C00227/2

0: Included

Change of parameter set: MXI2

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00254 | Phase controller gain

Data type: UNSIGNED_32

Index: 24321

d

= 5F01

h

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

1/s

1000.00 20.00 1/s

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00270 | Freq. - current setpoint filter

Data type: UNSIGNED_32

Index: 24305

d

= 5EF1

h

Set current setpoint filter (band-stop filter)

Setting range

(min. value | unit | max. value)

1.0

Hz

1000.0

Subcodes

Lenze setting

Info

C00270/1

200.0 Hz

Freq. - current setp. filter 1

C00270/2

400.0 Hz

Freq. - current setp. filter 2

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Parameter | Name:

C00271 | Width - current setp. filter

Data type: UNSIGNED_32

Index: 24304

d

= 5EF0

h

Set current setpoint filter (band-stop filter)

Setting range

(min. value | unit | max. value)

0.0

Hz

500.0

Subcodes

Lenze setting

Info

C00271/1

20.0 Hz

Width current setp. filter 1

C00271/2

40.0 Hz

Width current setp. filter 2

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10