C00276 | signal source - torque setpoint, C00280 | filter time const. dc detection, C00281 | filter for pwm adjustment – Lenze 9400 User Manual

Page 763: C00276, Tting, 14 parameter reference

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

763

14

Parameter reference

14.2

Parameter list | C00276

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00276

C00280

C00281

C00308

Parameter | Name:

C00276 | Signal source - torque setpoint

Data type: UNSIGNED_16

Index: 24299

d

= 5EEB

h

Selection list

(Lenze setting printed in bold)

Info

0 TorqueAdd/AccAdd signal
1 Differentiated SpeedSet signal
2 2x diff. PosSet signal
3 Differentiated SpeedAdd signal

From software version V5.0

This alternative selection to the differentiated SpeedSet

signal is recommended if the position controller works

with a high gain.

By the position controller also troubles within to the

actual position value are detected and like this reach the

speed setpoint. In the following differentiation of the

feedforward control, these troubles in particular in the

case of high position controller gains result in a very

unsettled torque feedforward control value. By means of

this selection the problem can be avoided, because then

only the trouble-free speed feedforward control value is

differentiated.

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00280 | Filter time const. DC detection

Data type: UNSIGNED_32

Index: 24295

d

= 5EE7

h

Setting range

(min. value | unit | max. value)

Lenze setting

1.0

ms

1000.0 25.0 ms

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Parameter | Name:

C00281 | Filter for PWM adjustment

Data type: UNSIGNED_8

Index: 24294

d

= 5EE6

h

From software version V7.0

The output voltage of the inverter is generated from the DC-bus voltage by a pulse width modulation (PWM). The

product from the DC-bus voltage and the control factor of the PWM corresponds to the height of the output voltage.

If the DC-bus voltage changes due to mains fluctuations or load changes, the control factor of the PWM must be

adapted if the output voltage is to remain constant. This correction is carried out in the control software by

measuring the DC-bus voltage. In order that no response takes place to faults in the DC-bus voltage measurement,

a filter can be activated for the measured signal via this parameter.

• The filter time constant is selected so that a quick correction can be carried out even under bad EMC conditions.

• A disadvantage of this filter is that the responses to real flickers on the DC-bus voltage are too slow. In

positioning tasks, this may cause an extreme increase of the following error.

• Under good EMC conditions, this filter is not required (Lenze setting).

• For devices > BF7 the filter is ineffective.

Selection list

(Lenze setting printed in bold)

0 Deactivated
1 Activated

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00308 | Service code

Data type: UNSIGNED_16

Index: 24267

d

= 5ECB

h

This code is for device-internal use only and must not be written to by the user!