C00314 | can tpdo4 mask byte x, C00320 | can tpdox identifier, C00320/1 – Lenze 9400 User Manual

Page 766: C00320/2, C00320/3, C00320/4, Es of, C00320, C00314/1, 14 parameter reference

Advertising
background image

14

Parameter reference

14.2

Parameter list | C00314

766

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00314

C00320

Parameter | Name:

C00314 | CAN TPDO4 mask byte x

Data type: BITFIELD_8

Index: 24261

d

= 5EC5

h

A mask can be parameterised for each byte of the TPDO4 in the assigned subcode.

• In case of an event-controlled PDO transmission, only the masked bits will be considered for event control.

• Mask "0x0" means that no bit of the corresponding byte actuates the transmission.

• Mask "0xff" means that every bit of the corresponding byte can actuate the transmission.

"CAN on board" system bus

Setting range
0x00

0xFF

Value is bit-coded:

Bit 0 Mask bit 0

... ...

Bit 7 Mask bit 7

Subcodes

Lenze setting

Info

C00314/1

0x00

Mask for byte 1 ... byte 8 of TPDO4

C00314/...
C00314/8

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00320 | CAN TPDOx identifier

Data type: BITFIELD_32

Index: 24255

d

= 5EBF

h

Identifier for TPDO1 ... TPDO4

• If bit 31 is set (0x8nnnnnnn), the TPDO is deactivated.

• The basic setting is according to the "Predefined Connection Set".

• Mapping of the CANopen objects

I-1800/1

...

I-1803/1

(see DS301 V4.02).

"CAN on board" system bus

Setting range
0x00000000

0xFFFFFFFF

Value is bit-coded:

Info

Bit 0 COB-ID bit 0

• Bit 0 ... 10: COB-ID

• Bit 11 ... 30: Reserved

• Bit 31: PDO invalid

... ...

Bit 31 PDO invalid

Subcodes

Lenze setting

Info

C00320/1

0x00000181

TPDO1 identifier

• After a node address change and CAN reset node, the

value 0x180 + node address will be set by default.

C00320/2

0x00000281

TPDO2 identifier

• After a node address change and CAN reset node, the

value 0x280 + node address will be set by default.

C00320/3

0x00000381

TPDO3 identifier

• After a node address change and CAN reset node, the

value 0x380 + node address will be set by default.

C00320/4

0x00000481

Identifier TPDO4

• After a node address change and CAN reset node, the

value 0x480 + node address will be set by default.

Read access  Write access  CINH  PLC STOP  No transfer