_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00356

C00357

C00359

Parameter | Name:

C00356 | CAN TPDOx cycle time

Data type: UNSIGNED_16

Index: 24219

d

= 5E9B

h

TPDO event time according to DS301 V4.02

• If the value is entered that is not "0", the TPDO is transmitted without further consideration of the transport type

after the set time has elapsed.

• Mapping of the CANopen objects

I-1800/5

...

I-1803/5

(see DS301 V4.02).

"CAN on board" system bus

Setting range

(min. value | unit | max. value)

0

ms

65535

Subcodes

Lenze setting

Info

C00356/1

0 ms

Cycle time for TPDO1 ... TPDO4

C00356/...
C00356/4

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00357 | CAN RPDOx monitoring time

Data type: UNSIGNED_16

Index: 24218

d

= 5E9A

h

Mapping of the RPDO event time (see DS301 V4.02)

• If a value unequal to "0" is entered, the RPDO is not expected before the set time has expired.

• If the RPDO is not received within this time, a parameterisable error message can be activated.

"CAN on board" system bus

Setting range

(min. value | unit | max. value)

0

ms

65535

Subcodes

Lenze setting

Info

C00357/1

3000 ms

Monitoring time for RPDO1 ... RPDO4

C00357/...
C00357/4

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00359 | CAN status

Data type: UNSIGNED_8

Index: 24216

d

= 5E98

h

"CAN on board" system bus

Selection list

(read only)

0 Operational
1 Pre-operational
4 Boot-up
5 Stopped
7 Reset
8 Initialisation
9 Unknown

10 Baud rate autom. detected

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Advertising