14

Parameter reference

14.2

Parameter list | C00374

778

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00374

C00375

Parameter | Name:

C00374 | CAN SDO client node address

Data type: UNSIGNED_8

Index: 24201

d

= 5E89

h

Node address of the client assigned to this server (see DS301 V4.02).

"CAN on board" system bus

Setting range

(min. value | unit | max. value)

1

127

Subcodes

Lenze setting

Info

C00374/1

1

SDO server channel 1 remote client node address

• Subcode 1 contains the basic SDO channel which,

according to DS301 V4.02, does not feature this entry.

Writing to the subcode has no effect.

• The value of subindex 1 results in 0.

C00374/2

1

SDO server channel 2 remote client node address

C00374/3

1

SDO server channel 3 remote client node address

C00374/4

1

SDO server channel 4 remote client node address

C00374/5

1

SDO server channel 5 remote client node address

C00374/6

1

SDO server channel 6 remote client node address

C00374/7

1

SDO server channel 7 remote client node address

C00374/8

1

SDO server channel 8 remote client node address

C00374/9

1

SDO server channel 9 remote client node address

C00374/10

1

SDO server channel 10 remote client node address

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00375 | CAN SDO client Rx identifier

Data type: BITFIELD_32

Index: 24200

d

= 5E88

h

Identifier which serves to reach the assigned SDO client.

• If bit 31 is set (0x8nnnnnnn), the corresponding SDO client channel is deactivated (see DS301 V4.02).

• The client channels need not be parameterised right now. Their functionality will only be required when using

the gateway services.

"CAN on board" system bus

Setting range
0x00000000

0xFFFFFFFF

Value is bit-coded:

Info

Bit 0 COB-ID bit 0

• Bit 0 ... 10: COB-ID

• Bit 11 ... 30: Reserved

• Bit 31: SDO invalid

... ...

Bit 31 SDO invalid

Subcodes

Lenze setting

Info

C00375/1

0x80000000

SDO client channel 1 RX ... 10 RX

C00375/...
C00375/10

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1