C00418 | activate resolver error compensation, C00420 | number of encoder increments, C00421 | encoder voltage – Lenze 9400 User Manual

Page 787: C00422 | encoder type, C00423 | ssi encoder: bit rate, C00422, C00420, C00421, C00418, C00423

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

787

14

Parameter reference

14.2

Parameter list | C00418

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00418

C00420

C00421

C00422

C00423

Parameter | Name:

C00418 | Activate resolver error compensation

Data type: UNSIGNED_8

Index: 24157

d

= 5E5D

h

From software version V7.0

Resolver error compensation

Selection list

(Lenze setting printed in bold)

0 Deactivated
1 Activated

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00420 | Number of encoder increments

Data type: UNSIGNED_16

Index: 24155

d

= 5E5B

h

Setting range

(min. value | unit | max. value)

Lenze setting

1

16384 512

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00421 | Encoder voltage

Data type: UNSIGNED_16

Index: 24154

d

= 5E5A

h

Setting range

(min. value | unit | max. value)

Lenze setting

5.0

V

12.0 5.0 V

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Parameter | Name:

C00422 | Encoder type

Data type: UNSIGNED_16

Index: 24153

d

= 5E59

h

Selection list

(Lenze setting printed in bold)

Info

0 Incremental encoder (TTL signal)
1 Sin/cos encoder
2 Absolute value encoder (Hiperface)
3 Absolute value encoder (EnDat)
4 SSI encoder

From software version V5.0

Use of an SSI encoder at X8

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00423 | SSI encoder: Bit rate

Data type: UNSIGNED_32

Index: 24152

d

= 5E58

h

From software version V5.0

Use of an SSI encoder at X8

Setting range

(min. value | unit | max. value)

Lenze setting

150

kbps

1000 400 kbps

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1