C00424 | ssi encoder: data word length, C00427 | ttl encoder signal evaluation, C00435 | ssi encoder: partword start position – Lenze 9400 User Manual

Page 788: C00424, C00427, C00435/1, 14 parameter reference

Advertising
background image

14

Parameter reference

14.2

Parameter list | C00424

788

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00424

C00427

C00435

Parameter | Name:

C00424 | SSI encoder: Data word length

Data type: UNSIGNED_32

Index: 24151

d

= 5E57

h

From software version V5.0

Use of an SSI encoder at X8

Setting range

(min. value | unit | max. value)

Lenze setting

1

Bit

31 25 bits

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00427 | TTL encoder signal evaluation

Data type: UNSIGNED_16

Index: 24148

d

= 5E54

h

Selection list

(Lenze setting printed in bold)

0 4x evaluation (A, B)
1 A:Increments B:Sign
2 Increments A:pos. B:neg.

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00435 | SSI encoder: partword start position

Data type: UNSIGNED_8

Index: 24140

d

= 5E4C

h

From software version V5.0

Use of an SSI encoder at X8

Setting range

(min. value | unit | max. value)

0

30

Subcodes

Lenze setting

Info

C00435/1

0

SSI enc.: Partword 1 start

C00435/2

0

SSI enc.: Partword 2 start

C00435/3

0

SSI enc.: Partword 3 start

C00435/4

0

SSI enc.: Partword 4 start

C00435/5

0

Ssi-enc.: Partword 5 start

C00435/6

0

SSI enc.: Partword 6 start

C00435/7

0

SSI enc.: Partword 7 start

C00435/8

0

Ssi-enc.: Partword 8 start

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Advertising