14

Parameter reference

14.2

Parameter list | C00436

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00436

C00437

Parameter | Name:

C00436 | SSI encoder: partword length

Data type: UNSIGNED_8

Index: 24139

d

= 5E4B

h

From software version V5.0

Use of an SSI encoder at X8

Setting range

(min. value | unit | max. value)

0

31

Subcodes

Lenze setting

Info

C00436/1

31

SSI enc.: Partword 1 length

C00436/2

0

SSI enc.: Partword 2 length

C00436/3

0

SSI enc.: Partword 3 length

C00436/4

0

SSI enc.: Partword 4 length

C00436/5

0

SSI enc.: Partword 5 length

C00436/6

0

SSI enc.: Partword 6 length

C00436/7

0

SSI enc.: Partword 7 length

C00436/8

0

SSI enc.: Partword 8 length

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00437 | SSI encoder: partword data coding

Data type: UNSIGNED_8

Index: 24138

d

= 5E4A

h

From software version V5.0

Use of an SSI encoder at X8

Selection list

(Lenze setting printed in bold)

0 binary coded
1 gray coded

Subcodes

Lenze setting

Info

C00437/1

0: binary coded

SSI enc.: Partword 1 coding

C00437/2

0: binary coded

SSI enc.: Partword 2 coding

C00437/3

0: binary coded

SSI enc.: Partword 3 coding

C00437/4

0: binary coded

SSI enc.: Partword 4 coding

C00437/5

0: binary coded

SSI enc.: Partword 5 coding

C00437/6

0: binary coded

SSI enc.: Partword 6 coding

C00437/7

0: binary coded

SSI enc.: Partword 7 coding

C00437/8

0: binary coded

SSI enc.: Partword 8 coding

Read access  Write access  CINH  PLC STOP  No transfer