C00585 | resp. to motor overtemp. ptc, C00586 | resp. to resolver open circuit, C00587 | fan control status – Lenze 9400 User Manual

Page 798: C00586, C00585, Ptc temperature in, Instead, 14 parameter reference

Advertising
background image

14

Parameter reference

14.2

Parameter list | C00585

798

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00585

C00586

C00587

Parameter | Name:

C00585 | Resp. to motor overtemp. PTC

Data type: UNSIGNED_32

Index: 23990

d

= 5DB6

h

Response if motor temperature across PTC input T1/T2 too high.
Selection list

(Lenze setting printed in bold)

1 Fault
5 Warning
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00586 | Resp. to resolver open circuit

Data type: UNSIGNED_32

Index: 23989

d

= 5DB5

h

Response to open circuit in resolver
Danger!

If the resolver is used as motor encoder:

In the event of an error, a safe operation of the motor cannot be ensured anymore!

For safety reasons, the "Fault" response should always be set for this case!
Selection list

(Lenze setting printed in bold)

1 Fault
2 Trouble
5 Warning
4 Warning locked
3 Quick stop by trouble

13 Quick Stop open loop by trouble

0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00587 | Fan control status

Data type: BITFIELD_8

Index: 23988

d

= 5DB4

h

Display area
0x00

0xFF

Value is bit-coded:

Bit 0 Heatsink fan ON
Bit 1 Integral fan ON
Bit 2 Heatsink fan status 1
Bit 3 Heatsink fan status 2
Bit 4 Integral fan status
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1