14

Parameter reference

14.2

Parameter list | C00612

804

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00612

C00613

Parameter | Name:

C00612 | Resp. to CAN node guarding error

Data type: UNSIGNED_8

Index: 23963

d

= 5D9B

h

Response of master if the corresponding node guarding response is not received.

"CAN on board" system bus: node guarding protocol

Selection list

(Lenze setting printed in bold)

1 Fault
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information
0 No response

Subcodes

Lenze setting

Info

C00612/1

0: No response

Response to non-received telegram for monitoring entry

1 ... 32

C00612/...
C00612/32

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00613 | Resp. to CAN heartbeat error

Data type: UNSIGNED_8

Index: 23962

d

= 5D9A

h

Response if the corresponding heartbeat telegram is not received.

"CAN on board" system bus: heartbeat protocol

Selection list

(Lenze setting printed in bold)

1 Fault
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information
0 No response

Subcodes

Lenze setting

Info

C00613/1

0: No response

Response to non-received telegram for monitoring entry

1 ... 32

C00613/...
C00613/32

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1